AWX O2-4 25
Mini 4-Series
- Nominal Range 0 – 25%
- Maximum Overload 30 %
- Expected Operation Life 2 years
- Output Signal .10 +/- 0.02 mA in Air
- Resolution 0.1 %
- Temperature Range - 20 °C to + 50 °C
- Pressure Range Atmospheric +/- 20 %
- t90 Response Time < 15 sec
- Relative Humidity Range 5 % to 95 % R.H. non-condensing
- Expected Long Term Output Drift < 2 % signal loss/month
- Recommended Load Resistor 100 Ohm
- Bias Voltage Not required
- Repeatability < 2 % of signal
- Output Linearity Linear
-
AWX O2-7 25
Compact 7-Series
- Nominal Range 0 – 25%
- Maximum Overload 30 %
- Expected Operation Life 2 years
- Output Signal .10 +/- 0.02 mA in Air
- Resolution 0.1 %
- Temperature Range - 20 °C to + 50 °C
- Pressure Range Atmospheric +/- 20 %
- t90 Response Time < 15 sec
- Relative Humidity Range 5 % to 95 % R.H. non-condensing
- Expected Long Term Output Drift < 2 % signal loss/month
- Recommended Load Resistor 100 Ohm
- Bias Voltage Not required
- Repeatability < 2 % of signal
- Output Linearity Linear